The role of continuous monitoring in a 24/7 telecardiology consultation service—a feasibility study

  • Kjell Nikus, MD

      Affiliations

    • Department of Cardiology, Heart Center, Tampere University Hospital, Tampere, Finland
    • Corresponding Author InformationCorresponding author. Department of Cardiology, Heart Center, Tampere University Hospital, Biokatu 6, 33520 Tampere, Finland.
  • ,
  • Jaakko Lähteenmäki

      Affiliations

    • VTT, Technical Research Centre of Finland, Espoo, Finland
  • ,
  • Pasi Lehto, MD

      Affiliations

    • Department of Cardiology, Heart Center, Tampere University Hospital, Tampere, Finland
  • ,
  • Markku Eskola, MD

      Affiliations

    • Department of Cardiology, Heart Center, Tampere University Hospital, Tampere, Finland

Received 18 April 2009

  • Image Result

    Remote surveillance view of central monitor display of arrhythmic events in a patient with an implanted cardioverter defibrillator.

    Remote surveillance view of central monitor display of arrhythmic events in a patient with an implanted cardioverter defibrillator.

  • Image Result

    Technical aspects of remote access from the telecardiologist's laptop computer to the hospital. The VPN solution provided a secure connection to the hospital intranet based on smart card authenticatio

    Technical aspects of remote access from the telecardiologist's laptop computer to the hospital. The VPN solution provided a secure connection to the hospital intranet based on smart card authentication. A fixed Internet connection using an ADSL was used as the physical access technology.

  • Image Result
    An alarm showing ventricular tachycardia with attempt for conversion to sinus rhythm by antitachycardia pacing by the implanted cardioverter defibrillator device.

    An alarm showing ventricular tachycardia with attempt for conversion to sinus rhythm by antitachycardia pacing by the implanted cardioverter defibrillator device.

  • Image Result
    Alarm showing nonsustained ventricular tachycardia.

    Alarm showing nonsustained ventricular tachycardia.

  • Image Result
    Trend curve showing rapid ventricular rate in atrial fibrillation in a patient postbypass surgery.

    Trend curve showing rapid ventricular rate in atrial fibrillation in a patient postbypass surgery.

  • Image Result
    Alarm for loss of capture in a patient with temporary pacing through epicardial leads postheart surgery.

    Alarm for loss of capture in a patient with temporary pacing through epicardial leads postheart surgery.

  • Image Result
    ST-deviation trends in channels V2 and V5 from the derived 12-lead EASI ECG system indicating episodes of myocardial ischemia.

    ST-deviation trends in channels V2 and V5 from the derived 12-lead EASI ECG system indicating episodes of myocardial ischemia.

  • Image Result
    Motion artifact simulating ventricular tachycardia revealed by second channel.

    Motion artifact simulating ventricular tachycardia revealed by second channel.

PII: S0022-0736(09)00277-5

doi: 10.1016/j.jelectrocard.2009.07.005