Journal of Electrocardiology
Volume 43, Issue 1 , Pages 48-53, January 2010

Filtered QRS duration on signal-averaged electrocardiography correlates with ventricular dyssynchrony assessed by tissue Doppler imaging in patients with reduced ventricular ejection fraction

  • Tatsuya Tahara, MD

      Affiliations

    • Division of Cardiology, Takamatsu Red Cross Hospital, Takamatsu, Japan
  • ,
  • Taiji Sogou, MD

      Affiliations

    • Division of Cardiology, Takamatsu Red Cross Hospital, Takamatsu, Japan
  • ,
  • Chisato Suezawa, MD

      Affiliations

    • Division of Cardiology, Takamatsu Red Cross Hospital, Takamatsu, Japan
  • ,
  • Hitoshi Matsubara, MD

      Affiliations

    • Division of Cardiology, Takamatsu Red Cross Hospital, Takamatsu, Japan
  • ,
  • Norihiro Tada, MD

      Affiliations

    • Division of Cardiology, Takamatsu Red Cross Hospital, Takamatsu, Japan
  • ,
  • Sho Tsushima, MD

      Affiliations

    • Division of Cardiology, Takamatsu Red Cross Hospital, Takamatsu, Japan
  • ,
  • Tomoki Kitawaki, DEng

      Affiliations

    • Department of Medical Technology, Okayama University Graduate School of Health Sciences, Okayama, Japan
  • ,
  • Ryoko Shinohata, PhD

      Affiliations

    • Department of Medical Technology, Okayama University Graduate School of Health Sciences, Okayama, Japan
  • ,
  • Shozo Kusachi, MD

      Affiliations

    • Department of Medical Technology, Okayama University Graduate School of Health Sciences, Okayama, Japan
    • Corresponding Author InformationCorresponding author. Department of Medical Technology, Okayama University Graduate School of Health Sciences, 2-5-1 Shikata-cho, Okayama 700-8558, Japan.

Received 30 January 2009 published online 16 July 2009.

Abstract 

Objectives

The relationships between filtered QRS duration and ventricular dyssynchrony were studied.

Methods

We measured filtered QRS duration on signal-averaged electrocardiography and analyzed tissue Doppler imaging in chronic heart failure patients with ejection fraction less than 50%.

Results

In 64 patients, interventricular and intraventricular dyssynchronies were observed in 25 and 38 patients, respectively. All patients with interventricular dyssynchrony were associated with intraventricular dyssynchrony. Filtered QRS showed 0.82 and 0.78 of the area under the curve (AUC) in the receiver operating characteristic curve (ROC) for the detection of interventricular and intraventricular dyssynchrony, respectively, with 89.7% and 96.2% specificity and 52.0% and 52.6% sensitivity, with cutoff values of 174 and 153 milliseconds. Specificity and sensitivity as well as AUC were lower in the ROC of QRS duration than filtered QRS duration.

Conclusion

Filtered QRS duration provided more reliable information to estimate ventricular dyssynchrony in patients with reduced ventricular ejection fraction than QRS duration did.

Keywords: QRS, Electrocardiography, Ventricular dyssynchrony

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-0736(09)00249-0

doi:10.1016/j.jelectrocard.2009.06.005

Journal of Electrocardiology
Volume 43, Issue 1 , Pages 48-53, January 2010