Journal of Electrocardiology
Volume 36 , Pages 145-150 , December 2003

Development of a new QT algorithm with heterogenous ECG databases

  • Günter Schreier, PhD

      Affiliations

    • ARC Seibersdorf Research GmbH, Biosignal Processing and Telemedicine, Graz, Austria
    • Corresponding Author InformationReprint requests: Günter Schreier, PhD, ARC Seibersdorf research GmbH, Biosignal Processing and Telemedicine, Grottenhofstrasse 3, 8053, Graz, Austria
  • ,
  • Dieter Hayn, MSc

      Affiliations

    • ARC Seibersdorf Research GmbH, Biosignal Processing and Telemedicine, Graz, Austria
  • ,
  • Suave Lobodzinski, PhD

      Affiliations

    • California State University, Long Beach, CA, USA

References 

  1. Laguna P, Mark RG, Goldberger A, et al.  A database for evaluation of algorithms for measurement of QT and other waveform intervals in the ECG. Comput Cardiol. 1997;24:673
  2. Moody GB, Mark RG, Goldberger AL. PhysioNet (A Web-based resource for the study of physilogic signals). IEEE Eng Med Biol Mag. 1998;20:70
  3. The CSE working party . Recommendations for measurement standards in quantitative electrocardiography. Euro Heart J. 1985;6:815
  4. Schreier G, Kastner P, Marko W. An automatic ECG processing algorithm to identify patients prone to paroxysmal atrial fibrillation. Comput Cardiol. 2001;28:133
  5. Savelieva I, Yap YG, Yi G, et al.  Comparative reproducibility of QT, QT peak and T Peak-T End intervals and dispersion in normal subjects, patients with myocardial infarction and patients with hypertrophic cardiomyopathy. Pacing Clin Electrophysiol. 1998;21:2376
  6. Batchvarov V, Yi G, Guo X, et al.  QT interval and QT dispersion measured with the threshold method depend on threshold level. Pacing Clin Electrophysiol. 1998;21:2372
  7. Di Bernardo D, Langley P, Murray A. Dispersion of QT intervals (A measure of dispersion of repolarization or simply a projection effect?). Pacing Clin Electrophysiol. 2000;23:1392
  8. Laguna P, Jane R, Caminal P. Automatic detection of wave boundaries on multilead ECG signals (Validation with the CSE database). Comput Biomed Res. 1994;27:45
  9. Martinez JP, Olmos S, Laguna P. Evaluation of a wavelet-based ECG waveform detector on the QT database. Comput Cardiol. 2000;27:81
  10. Willems JL, Arnaud P, Van Bemmel JH. Assessment of the performance of electrocardiographic computer programs with the use of a reference database. Circulation. 1985;71:523

PII: S0022-0736(03)00127-4

doi: 10.1016/j.jelectrocard.2003.09.039

Journal of Electrocardiology
Volume 36 , Pages 145-150 , December 2003