Safe right bundle branch block pattern during permanent right ventricular pacing☆
Article Outline
Abstract
It is known that an electrocardiogram (ECG) after transvenous right ventricular (RV) pacing should yield left bundle branch block (LBBB) QRS patterns. When right bundle branch block (RBBB) pacing morphology appears in a patient with a permanent or temporary transvenous RV pacemaker, myocardial perforation or malposition of the pacing lead must be ruled out, even though the patient may be asymptomatic. We report a case of a 77-year-old man who underwent permanent transvenous VDD pacemaker implantation for symptomatic heart block. The postoperative ECG revealed a RBBB pacing configuration, but his chest X-ray and echocardiographic studies confirmed uncomplicated RV pacing. We review and discuss the literature concerning the differential diagnosis of such a safe RBBB ECG pattern.
Keywords: Ventricular pacing, right bundle branch block, pacing lead
No full text is available. To read the body of this article, please view the PDF online.
References
- Radiographic demonstration of myocardial perforation by permanent endocardial pacemaker. Radiology. 1971;98:35
- . Perforation of the interventricular septum by transvenous pacemaker catheter. Am J Cardiol. 1969;24:269
- . Malplacement of pacemaker catheters in the coronary sinus. J Thorac Cardiovasc Surg. 1969;57:511
- Malposition of transvenous pacing lead in the left ventricle. PACE. 1993;16:1800
- Transarterial permanent pacing of the left ventricle. PACE. 1990;13:588
- Unusual QRS morphology associated with transvenous pacemaker. Chest. 1985;87:517
- . Incidence and electrocardiographic localization of safe right bundle branch block configuration during permanent ventricular pacing. Am J Cardiol. 1995;76:781
- . Evaluation of unusual QRS complexes produced by pacemaker stimuli-with special reference to the vectorcardiographic and echocardiographic findings. J Electrocardiol. 1980;13:409
- Effect of pacemaker site on cardiac output and ventricular activation in dogs with complete heart block. Am J Cardiol. 1964;14:494
- . Unusual patterns of conduction produced by pacemaker stimuli. Am Heart J. 1967;74:24
- Significance of right bundle-branch block patterns during pervenous ventricular pacing. Br Heart J. 1969;31:285
- . Unusual QRS wave forms associated with permanent pacemakers. Chest. 1973;64:480
☆ Reprint requests: Wei-Hsian Yin, MD, Division of Cardiology, Department of Internal Medicine, Cheng-Hsin General Hospital, 45 Cheng-Hsin St, Pei-Tou, Taipei, Taiwan,R.O.C.; e-mail: yin.wh@msa.hinet.net.
PII: S0022-0736(02)30453-9
doi:10.1054/jelc.2003.50002
© 2003 Elsevier Science (USA). All rights reserved.